Pulmonary Insufficiency: Difference between revisions

No edit summary
 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
==Quantification Pulmonaliklep insufficiency==
==Quantification Pulmonary valve insufficiency<cite>1</cite>==


{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="500px"
{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="800px"
|-
|-
!
!width="200px"|
!Slight  
!Slight  
!Moderate  
!Moderate  
Line 10: Line 10:
!RV dimension  
!RV dimension  
|normal  
|normal  
|normal/dilated  
|normal / dilated  
|dilated
|dilated
|-
|-
Line 19: Line 19:
|-
|-
!Systolic flow in pulmonary artery
!Systolic flow in pulmonary artery
decreased in decreased slightly decreased slightly
|decreased slightly
!Color Doppler signal narrow jet located under pulmonary wide level jet far into RV reaching broad retrograde jet outbound portion of pulmonary branches
|decreased slightly
 
|decreased
Source: European Journal of Echocardiography (2010 ) 11, 223-244
|-
!Color Doppler signal
|narrow jet located under pulmonary valve level
|wide jet reaching far into RV
|wide retrograde jet outbound portion of pulmonary branches
|}
 
 
==Color doppler==
==Color doppler==
With color Doppler , the degree of expansion of the jet flow back into the right ventricle can be used to quantify the degree of pulmonary insufficiency enigzinds it is most commonly used .
With color Doppler, the degree of expansion of the jet flow back into the right ventricle can be used to quantify the degree of pulmonary insufficiency enigzinds it is most commonly used .


==Continuous wave==
==Continuous wave==
Also by continuous wave signal with an impression can be gekeregen on the severity of the pulmonary valve insufficiency.
Also by continuous wave signal with an impression can be gekeregen on the severity of the pulmonary valve insufficiency.


[[Image:PI01.png]]
{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="800px"
|-
|[[Image:PI01.png|800px]]
|-
|'''A''' ''Minimum insufficiency as seen in normal individuals:'' holodiastolic signal dip by atrial contraction.
 
'''B''' ''Light insufficiency:'' holodiastolic backflow small reversal following atrial contraction only during inspiration.


A Minimum insufficiency as seen in normal individuals : holodiastolisch signal dip by atrial contraction
'''C''' ''Moderate insufficiency:'' return of the return current to zero before the end of diastole to late diastolic antegrade flow in the pulmonary artery due to the atrial contraction both in inspiration and in expiration.
B Light insufficiency : holodiastolische backflow small reversal following atrial contraction only during inspiration
C Moderate insufficiency : return of the return current to zero before the end of diastole to late diastolic antegrade flow in the pulmonary artery due to the atrial contraction both in inspiration and in expiration.
D Severe insufficiency : short sharp backflow indicating rapid equilibration of pulmonary and RV diastolic and end-diastolic pressure with mid forward flow in the pulmonary artery .
Source : Mulder B.J.M. , P. G. Pieper , Spitaels S.E.C. Congenital heart disease in adults . Bohn Stafleu of Loghum Houten / Diegem 1999


example
'''D''' ''Severe insufficiency:'' short sharp backflow indicating rapid equilibration of pulmonary and RV diastolic and end-diastolic pressure with mid forward flow in the pulmonary artery.<cite>2</cite>
|}


[[Image:Pi01.jpg]]
===Example===


Moderate pulmonary insufficiency
{| class="wikitable" cellpadding="0" cellspacing="0" border="0"
|-
|[[Image:Pi01.jpg|400px]]
|-
!Moderate pulmonary insufficiency
|}


==References==
==References==
<biblio>
<biblio>
#1 pmid=20375260
#1 pmid=20375260
#2 Mulder B.J.M., Pieper P.G., Spitaels S.E.C. Aangeboren hartafwijkingen bij volwassenen. Bohn Stafleu van Loghum Houten/Diegem 1999
</biblio>
</biblio>
0

edits